8370 series duplex filter unit is widely used for hydrogen cooling seal oil system of turbo generator and other auxiliary mechanical lubrication system. It can efficiently remove granular impurity and ensure reliable and high efficiency running of unit.
■ Optimized design.
■ High efficiency filter element.
■ Various filtration ratings are available
■ Stainless steel mesh distributes flow uniformly
■ Both visual and electronic differential pressure indicator are optional.
■ Differential pressure device on the machine, independent from bypass valve.
■ Indicator signaling before bypass valve open.
■ Standard O-ring seal
■ Ball valve for easy operation.
| Designed Pressure | 28 bar | |||
| Maximum Operating Pressure | 28 bar | |||
| Burst Pressure | 42 bar | |||
| Filter Element Collapse Pressure | 20 bar | |||
| Maximum Flow Rate | 1,200 L/min | |||
| Port Size | 2.5” , 3” | |||
| Operating Temperature | Nitrile Seal:-43 -107ºC; Fluorocarbon Seal:-29 -120ºC | |||
| Max. Temperature | 60℃with HWCF, Water or Glycol | |||